3D scanner for large objects MAX Elite
The 3D scanner for large objects MAX Elite provides high measurement accuracy. It reaches 0.040 mm. Volumetric accuracy is 0.020 ± 0.100 mm/m. The device has exceptional repeatability. This is confirmed by the corresponding certificate. Using the MAX Elite 3D scanner allows achieving a high level of detail when scanning. This is critical for accurate analysis and quality control directly in production.

TRUaccuracy dynamic alignment technology – accurate data in any conditions
TRUaccuracy™ dynamic referencing technology ensures independent accuracy that is not affected by scanner movements. Thanks to this technology, even object scanning fluctuations do not affect the quality of measurements. It remains consistently high. TRUaccuracy™ is a key element of Creaform's technological base. This allows the development of high-precision three-dimensional optical metrology systems.
Creaform offers automatic positioning and dynamic referencing. They ensure constant optical communication between the 3D scanner and the measurement object. This allows measurements to be taken even when the object and the device are in motion.
Features of Creaform HandySCAN MAX
- Weight: 1.22 kg
- Accuracy: up to 0.075 mm
- Volumetric accuracy: 0.075+0.010 mm/m
- Scanning speed: 2,250,000 points/s
- 38 blue laser lines
- Laser class 2M
- Part size range: 1-15 m
- Working distance: 0.30-2.5 m
- Scanning area: 1x1 m
- High level of detail when scanning parts of different sizes
- High production capacity and reliability
- Certified product (ISO 17025)
.jpg)
Metrological-grade accuracy can be obtained in workshop conditions
The Creaform HandySCAN MAX Elite 3D scanner provides accuracy up to 0.075 mm and a volumetric accuracy of 0.075 mm + 0.010 mm/m, making it ideal for applications requiring high detail.
Why is it difficult to achieve accuracy in workshop conditions?
Transferring control from the laboratory bench to the workplace offers significant advantages. However, this can create certain difficulties. These include equipment vibration. It also has high setup requirements. Temperature and humidity fluctuations are also observed. There are also differences in operator qualifications. The HandySCAN MAX is designed with these factors in mind. It provides consistently high results under any conditions.
Creaform HandySCAN MAX – an accurate device with excellent features and equipment
The scanner is equipped with 38 blue laser lines, allowing measurements at a speed of up to 2,250,000 points per second. The working distance ranges from 0.30 m to 2.50 m, and the depth of field is 2.20 m, providing flexibility in scanning objects of various sizes.
Fast and accurate scanning of objects of various sizes with complex surfaces
The recommended size of objects for scanning ranges from 1 to 15 meters, making it suitable for various industries, including aerospace, automotive, and heavy industry. The scanner has a measurement resolution of 0.04 mm and a mesh resolution of 0.4 mm, ensuring high detail in the resulting models.
.jpg)
Over 5,000 users worldwide can't be wrong!
The SILVER series is part of the HandySCAN 3D™ line. It is a recognized industry standard for portable metrological-grade 3D scanners. HandySCAN 3D uses patented technologies. They provide accurate and repeatable three-dimensional measurements. Measure objects of any complexity in any conditions.
Wide integration capabilities of the HandySCAN MAX Elite 3D scanner
The HandySCAN MAX Elite is compatible with a wide range of software, including Geomagic, PolyWorks, Metrolog X4, Spatial Analyzer, Verisurf, CATIA V5, SOLIDWORKS, Creo, NX, Solid Edge, Inventor, and PowerINSPECT. This ensures easy integration into existing workflows.
Mobility and compactness of the 3D scanner
The device weighs only 1.22 kg and has dimensions of 133 x 79 x 435 mm, making it portable and easy to use. Connection is via USB 3.0, and the operating temperature range is from 5 to 40 °C with humidity from 10 to 90%.
.jpg)
The device has passed certification according to ISO 17025 and more
The scanner is certified according to EC Compliance, IP50, and WEEE standards, which confirms its reliability and compliance with international requirements. It is also compatible with batteries, providing additional mobility.
The HandySCAN MAX Elite is a reliable solution for accurate and fast 3D scanning of large objects, providing high data quality and efficiency.
You can buy the HandySCAN MAX Elite in Ukraine with a guarantee and service today – call us!
| Light source | 38 blue laser lines |
| Volumetric Accuracy (mm/m) | 0,075 + 0,010 |
| Scanner type | Handheld |
| Additional extensions | MaxSHOT 3D™, Portable Workstation |
| Color scanning | No |
| Scan with marks | Yes |
| Part size range (m) | 1 - 10 |
| Scanning speed (points/s) | 2 250 000 |
| Scan Accuracy (mm) | 0,075 |
| Scan Range (mm) | 1000 × 1000 |
| Stand-off distance (mm) | 300-2500 |
| Scan Depth (mm) | 3,50 |
| Measurement Resolution (mm) | 0,05 |
| Point distance (mm) | 0,4 |
| Safety class | 2M (safe for eyes) |
| Supported file types | .dae, .fbx, .ma, .obj, .ply, .stl, .txt, .wrl, .x3d, .x3dz, .zpr, .3mf |
| Software | VXelements |
| Compatible Software | 3D Systems (Geomagic® Solutions), InnovMetric Software (PolyWorks), Metrologic Group (Metrolog X4), New River Kinematics (Spatial Analyzer), Verisurf, Dassault Systèmes (CATIA V5, SOLIDWORKS), PTC (Creo), Siemens (NX, Solid Edge), Autodesk (Inventor, PowerINSPECT) |
| Connectivity | USB 3.0 |
| System Requirements | HP ZBook 15, Intel Core i7 (6+ cores) – 2.6 GHz or more (must support AVX2 instructions), Windows 10 (64 bits), NVIDIA Quadro T1000 4 GB, OpenGL 4.5 and higher, Memory 64 GB, Solid-state drive (SSD) with at least 200 GB of free space |
| Weight Netto (kg) | 1,22 |
| Dimensions Netto (mm) | 133 × 79 × 435 |
| Manufacturer country | Canada |
| Warranty period (months) | 12 |
| Certifications | EC Compliance (Electromagnetic Compatibility Directive, Low Voltage Directive), IP50, WEEE, ISO 17025 |
| Patents | CA 2,600,926, CN 200680014069.3, US 7,912,673, CA 2,656,163, EP (FR, UK, DE) 1,877,726, AU 2006222458, US 8,032,327, JP 4,871,352, US 8,140,295, EP (FR, UK, DE) 2,278,271, EP (FR, UK, DE) 2,230,482, IN 266,573, US 7,487,063, CA 2,529,044, EP (FR, UK, DE) 3,102,908, US 15/114,563, CN 201580007340X |
| Suggested Operating Environment | |
| Operating Ambient Temperature (°C) | 5 - 40 |
| Operating Humidity Range (%) | 10 - 90 |